Explosion Proof 5x20mm Fast Acting Cartridge Tube Ceramic Fuse 10A 250V 300V 500V 700V
简介
5x20mm Fast Acting Ceramic Fuse is Explosion proof fuse inside with Quartz sand can withstand high voltage up to 700V and high breaking capacity.
Description of The 5x20mm Fast Acting Ceramic Fuse
5x20mm Fast Acting Ceramic Fuse with ceramic body provide a much higher level of protection against damage to the measurement devices when triggered than regular glass fuses.
Blown fuse may only be replaced with spare fuses of the same type and specifications to ensure the safety of the devices and thus the safety of the user during following measurements.
5.250/300/500/700 Series is the first and smallest 500VAC and 300VDC fuse under the class of 5x20mm fuse family. It is designed for circuit protection in the area of high energy applications.
With its DC and AC characteristics, this Series is well suited for high energy or power efficient applications and 3-phase power supplies protection respectively.
In addition, it has interrupting rating (0.5A to 16A) at 500Vdc which ensures the circuit is well protected under DC conditions.
Features of The 5x20mm Fast Acting Ceramic Fuse
DC interrupting current
100% Lead-Free and RoHS compliant
UL and CSA agency approval
Applications of The 5x20mm Fast Acting Ceramic Fuse
Input of 3 phase Power Supplies
Inverter in LCD backlight unit
DC side of air-conditioner unit
Size of The 5x20mm Fast Acting Ceramic Fuse
Specification of The 5x20mm Fast Acting Ceramic Fuse
5.250 series is 250V version,5.300 series is 300V version,5.500 series is 500V version and 5.700 series is 700V version.
Catalog | Ampere | Voltage | Breaking | I2TMelting |
No. | Rating | Rating | Capacity | Integral(A2.S) |
5.5000100A/B | 100mA | 250V 300V 500V 700V | 10000A@125 V AC (200mA~10A); 35A@250V AC (200mA~1A); 100A@250V AC (1.25A~3.5A); 200A@250V AC (4A~10A); 100A@500V AC (4A~10A). | 0.002 |
5.5000125A/B | 125mA | 0.003 |
5.5000160A/B | 160mA | 0.005 |
5.5000200A/B | 200mA | 0.01 |
5.5000250A/B | 250mA | 0.02 |
5.5000300A/B | 300mA | 0.04 |
5.5000315A/B | 315mA | 0.045 |
5.5000350A/B | 350mA | 0.055 |
5.5000400A/B | 400mA | 0.07 |
5.5000500A/B | 500mA | 0.1 |
5.5000630A/B | 630mA | 0.2 |
5.5000750A/B | 750mA | 0.35 |
5.5000800A/B | 800mA | 0.45 |
5.5001100A/B | 1A | 0.9 |
5.5001125A/B | 1.25A | 1.3 |
5.5001150A/B | 1.5A | 1.6 |
5.5001160A/B | 1.6A | 2.5 |
5.5001200A/B | 2A | 5.8 |
5.5001250A/B | 2.5A | 7.6 |
5.5001300A/B | 3A | 8.1 |
5.5001315A/B | 3.15A | 11 |
5.5001350A/B | 3.5A | 19 |
5.5001400A/B | 4A | 28 |
5.5001500A/B | 5A | 40 |
5.5001600A/B | 6A | 50 |
5.5001630A/B | 6.3A | 64 |
5.5001700A/B | 7A | 107 |
5.5001800A/B | 8A | 133 |
5.5002100A/B | 10A | 242 |
5.5002150A/B | 15A | 368 |
5.5002160A/B | 16A | 388 |
5.5002200A/B | 20A | 442 |
5.5002250A/B | 25A | 568 |
Electrical Characteristics of The 5x20mm Fast Acting Ceramic Fuse
UL248-1/14 % of Ampere Rating(In) | Blowing Time |
100%* In | 4 hours Min |
135%* In | 1 hour Max |
200%* In | 5 sec Max |
IEC60127 % of Ampere Rating(In) | Blowing Time |
210%* In | 30 min Max |
275%* In | 10ms – 2s |
Package of The 5x20mm Fast Acting Ceramic Fuse
Bulk,500pcs per bag and 5000pcs per box.
How to Choose the Right Fuse
Electrical and electronic devices all need some type of protection, which typically comes from fuses. Unlike circuit breakers, a fuse is a one-time protection that must be replaced after serving its purpose. Fuses range from small glass tubes to large main electrical-service equipment. Generally fuses are rated on the voltage they can control, speed of interruption and their size. Listed in the resources is a chart for applying those ratings to your particular application. Identifying a methodical approach is still needed for choosing any type of fuse, whether it is a replacement or for a new application.
Step 1
Identify the type of voltage that is being protected. Fuses are rated not only by the amount of voltage but whether it is direct current (DC) or alternating current (AC). Some fuses may be dual-rated—able to handle both DC and AC power. These ratings however will be different in the overall power that can be utilized for proper protection. Select a fuse that will fall into the voltage range of that particular circuit.
Step 2
Observe the amperage of the electrical circuit that the fuse will be protecting. Circuits that include motors or fluorescent lighting use wire coil windings. When starting, these coils of wire will have an "in-rush" of current. This in-rush will be greater than the actual power bring used once the device is running. Pick a fuse made for motor-starting or one that has a time-delay rating. This will allow the electrical load to be protected while the in-rush current may exceed the fuse's overall interruption rating.
Step 3
Size the fuse to its particular holder. There are specific fuse holders that will only physically connect to that type of fuse. These fuse-connection points are constructed not only so they will fit into a particular space but also for the fuse's characteristics. Small glass-tube fuses can only be replaced with those of like kind. Special time-delay fuses have a certain diameter and length. Other types of fuses of the same voltage and rating will not fit in that particular holder. Large knife-blade fuses that control high voltage and amperage cannot be replaced with fuses of a lesser capability.
Step 4
Inspect the fuse for internal element replacement. Some fuses carry an internal replaceable fused element. These pieces of electrically conductive metals are made to be withdrawn from a cylindrical container after they have "blown." A metal fuse strip is then placed back into the round cartridge and the circuit can be reset for power. Generally these fuse elements are sold in separate boxes and are rated in the same way as a one-time fuse.
Step 5
Use a fuse that has an inspection window. These windows will indicate whether or not the fuse has "blown." This type of fuse can be extremely helpful in industrial applications or for the home setting. A quick visual check is all that is needed for identifying a problem with electrical circuits.
Tip
When checking fuses with an ohmmeter, pull the fuse from its holder before using the meter. There will still be voltage applied to one side of the fuse. Fuse-pullers should always be used when servicing larger fuses of any kind. Fuse-pullers are insulated and will protect the user from shocks.